2 output signal cable selection, 4 cable and terminal connections, 1 input terminal connections – Yokogawa YTA320 User Manual

Page 25: Output signal cable selection -2, Cable and terminal connections -2 5.4.1, Input terminal connections -2, Warning, Caution

Advertising
background image

<5. Wiring>

5-2

IM 01C50B01-01E

When a thermocouple is used as the temperature

sensor, a compensation wire must be used that

it appropriate for the type of thermocouple (refer

to compensating cables for JIS C 1610/IEC584-3

thermocouples). When a resistance temperature

sensor (RTD) is used as the temperature sensor,

2-core/3-core/4-core cable must be used (refer

to resistance thermometer sensor JIS C 1604/

IEC751). The terminal of the dedicated cable is a 4

mm screw.

5.3.2 Output Signal Cable Selection

• With regard to the type of wire to be used

for wiring, use twisted wires or cables with

performance equivalent of 600V vinyl insulated

cable (JIS C3307).

• For wiring in areas susceptible to electrical

noise, use shielded wires.

• For wiring in high or low temperature areas, use

wires or cables suitable for such temperatures.

• For use in an atmosphere where harmful gases

or liquids, oil, or solvents are present, use wires

or cables made of materials resistant to those

substances.

• It is recommended that a self-sealing terminal

with insulation sleeve (4-mm screw) be used for

lead wire ends.

WARNING

If the YTA is TIIS flameproof and the ambient

temperature is 50°C or more, use an external

cable having a maximum allowable heat

resistance of at least 70°C in consideration of

the instrument’s generation of heat or the cable’s

self-heating.

5.4 Cable and Terminal

Connections

5.4. Input Terminal Connections

NOTE

It is recommended that the terminals be

connected in the order of input terminal (1) and

output terminal (2).

CAUTION

When wiring, pay attention not to damage the

cable and cores. All the cores of the cable must

have the sufficient insulation around them.

F0504.ai

a. Cable connection to thermometer resistor(RTD), 3-wire

b. Power supply cable connection

STEP 1

(1)

STEP 2

(2)

Figure 5.4

Terminal Connection Pro cedure

The temperature sensor is to be

connected as shown in Figures 5.6 and

5.7.

F0505.ai

Figure 5.5

Terminal diagram