Yokogawa YTA320 User Manual

Page 33

Advertising
background image

<6. Maintenance>

6-5

IM 01C50B01-01E

Table 6.3

Problems, Causes and Countermeasures

Observed

Problems

Possible Cause

Countermeasure

Related Parameter

(BRAIN protocol)

(HART protocol)

Output fluctuates

greatly.

Span is too narrow.

Check the range, and

change the settings to make

the span larger.

F10:LRV

F20:URV

PV LRV (4)

PV URV (5)

Input adjustment by

user was not corrctly

done.

Clear the user adjustment

(Sensor trim) value or set it

to off.

J05:SNSR1 CLR

K05:SNSR2 CLR

Snsr1 Trim Act

(123312)

Snsr2 Trim Act

(123322)

Output adjustment by

user was not correctly

done.

Clear the user adjustment

(output trim) value or set it

to off.

L05:OUT CLR

D/A Clr to Default

(12343)

Transmitter

outputs fixed

current.

The transmitter is in

manual (test output)

mode.

Release manual mode.

(Make the transmitter return

to Automatic Mode)

G10:OUTPUT MODE Loop test (122)

Input adjustment by

user was not corrctly

done.

Clear the user adjustment

(Sensor trim) value or set it

to off.

J05:SNSR1 CLR

K05:SNSR2 CLR

Snsr1 Trim Act

(123312)

Snsr2 Trim Act

(123322)

Output adjustment by

user was not correctly

done.

Clear the user adjustment

(output trim) value or set it

to off.

L05:OUT CLR

D/A Clr to Default

(12343)

Output is reversed.

(See note 1)

LRV is greater than

URV.

Set the correct value to URV

and LRV.

F10:LRV

F20:URV

PV LRV (4)

PV URV (5)

The transmitter is set to

reversed output mode.

Set the transmitter to normal

output mode.

H10:REVERSE OUT

Parameters cannot

be changed.

The transmitter is in

write protect status.

Release write protect.

H40:WRITE PROTCT Chng wrt Protect

(Hot key)

Sensor backup

function doesn’t

work correctly.

Settings of Process

Variables are not

correct.

Set Sensor1 as PV and

Sensor2 as SV.

B10:PV is

B20:SV is

PV is (11211)

SV is (11212)

Configuration of

Sensor1 and Sensor2 is

not correct.

• Check the type and wire

settings for Sensor1 and

Sensor2.

• Check the connection of

Sensor1 and Sensor2.

D10:SENSOR1 TYPE

E10:SENSOR2 TYPE

Snsr1 config (134)

Snsr2 config (135)

Sensor Burnout is set

to “off.”

Check the Sensor Burnout

setting.

F40:BURN OUT

Sensor barnout

(14315)

Sensor backup mode is

not enabled.

Change the Sensor Backup

function to “enable.”

H20:SNSR BACKUP

Snsr backup (14141)

Output damping

doesn’t work.

Damping time constant

is set to “0 second.”

Set correct value.

B12:PV DAMPING

PV damp (1322)

Setting for “PV damping

point” is too small.

If output fluctuation is great,

set a greater value for PV

damping point than current

setting. (Initial setting is “2%”

of output)

B13:DMP POINT

PV damp point

(1323)

Note 1: If the reversed output is desired and necessary setting was done by user, it is not considered as a problem.