Brocade Mobility RFS Controller System Reference Guide (Supporting software release 5.5.0.0 and later) User Manual
Page 244

232
Brocade Mobility RFS Controller System Reference Guide
53-1003099-01
5
Using an appropriate console terminal and or connection to your device log on to the CLI
and follow these steps:
rfs6000-xxxxxx>enable
rfs6000-xxxxxx #configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
rfs6000-xxxxxx (config)#profile BR71XX Non-Root BR71XX
rfs6000-xxxxxx (config-profile-Non-Root-BR71XX)#misconfiguration-recovery-time 0
rfs6000-xxxxxx (config-profile-Non-Root-BR71XX)
Overriding a Profile’s Environmental Sensor Configuration (BR1240
Only)
An BR1240 sensor module is a USB environmental sensor extension to an AP-8132 model Access
Point. It provides a variety of sensing mechanisms, allowing the monitoring and reporting of the
BR1240's radio coverage area. The output of the sensor's detection mechanisms are viewable
using either the Environmental Sensor screen.
To set or override an environmental sensor configuration for an BR1240 model Access Point:
1. Select the Configuration > Devices from the Web UI.
2. Select Profile Overrides to expand its menu items
3. Select Environmental Sensor.
FIGURE 116
Profile Overrides - Environmental Sensor screen