O 13v, O> 99.9, O 0.00 – HT instruments MACROTEST 5035 User Manual

Page 15: Vol ag

Advertising
background image

MACROTEST

5035

EN - 14

In case the mode R+TIMER or R-

TIMER was selected and a

R+ or R-

higher than 99.9

Ω was detected, the

instrument emits

an intermittent

sound signal during the test, a long
sound signal at the end of the test

and displays the screen alongside.

CAL LOW

o> 99.9

- - -

mA

4

s

R+


TIMER

In case that:

R

MEASURED

-R

CALIBRATION

< 0

Ω the

instrument displays the screen
alongside.

CAL LOW

o 0.00

219

mA

AUTO

SAVING:

The tests can be stored pressing the

SAVE key twice

(according to paragraph 5.1).

If the terminal voltage is higher than

10V, the instrument does not carry out
the test and displays the screen
alongside for 5 seconds after which, the
instrument displays the screen relative
to the precedent selected test mode
LOW

Ω under AUTO mode.

CAL LOW

o 13V

VOL AG


THIS RESULT CANNOT BE SAVED.

99.9

is the

maximum value.

ATTENTION:
value of R+ or R-
is too high.

Blinking

CAL.

ATTENTION: R

MEASURED

-R

CALIBRATION

< 0

AUTO mode.

SAVE

ATTENTION: the
test was not
effected
because
of voltage at the
terminal ends.

SAVE