Handbook BM 100 A

1 Agitator

2

Support beam perpendicular to the pulse
direction

3

Abrupt changes in tank cross section

4 Heating

tubes

5

Alternative solution: reference chamber -
electromagnetic field is contained within
chamber.

6

Gauge electromagnetic field :
Any intruding metallic object will be
detected in this zone if perpendicular to
the emitted pulse direction.

= Do not fit the process connection near to these objects.


Probe Type

Recommended minimum distance of probe from
objects inside the tank in millimetres (inches)

Single (types F, H and K)

300 (12)

Twin (types A, B, G and L)

100 (4)

Coaxial (type D)

0 (0)



Electromagnetic field shape around probe, by type (not to scale)

Single (types F, H and K)

Twin (types A, B, G and L)

Coaxial (type D)






No beam angle for any probe type.