KROHNE BM 100A Handbook User Manual

Page 16

Advertising
background image


16

Handbook BM 100 A


Traction on cable according to product (approximate value in metric tons)

Probe Length / m (ft)

Material Probe

used

10 (32.8)

20 (65.6) 30

(98.4)

Cement

Single cable Ш8 / Ш0.3’’

1.0 T / 2200 lb

2.0 T / 4410 lb

3.0 T / 6620 lb

Flyash

Single cable Ш8 / Ш0.3’’

0.5 T / 1100 lb

1.0 T / 2200 lb

1.5 T / 3300 lb

Wheat

Single cable Ш8 / Ш0.3’’

0.3 T / 660 lb

0.6 T / 1320 lb

1.2 T / 2650 lb

PE granules Twin cable Ш6 / Ш0.2’’

0.2 T / 440lb

0.6 T / 1320 lb

1.0 T / 2200lb



Electro static discharge (E.S.D.)

BM100 Standard and Ex gauge electronics are normally shielded up to 16KV against E.S.D.*.
*For non-Ex powder applications, BM100A probes are protected up to 32 kV.

Note:
E.S.D. cannot be solved by BM100A E.S.D. protection. It is the customer’s responsibility
to avoid E.S.D. by grounding the tank, product and probe installation.

1


Danger of injury

The probe may become electro
statically-charged during
operation; earth the probe by
pushing it against tank wall with a
suitably isolated tool just before
touching it to avoid receiving a
shock.

2

Earth the entry pipe and product.



Product deposits on the nozzle and probe

Product build-up can occur under the nozzle: this may weaken the pulse. Avoid cavities that permit
the build-up of deposits.


Tank roof deformation

Tank roofs should support loads of at least 3.5 tonnes / 7700lb for gauge installations using type K
single cable probes and 3.6 tonnes / 7900 lb for gauge installations using type B twin cable probes
without deformation.

Advertising