Handbook BM 100 A


How to configure displayed value and units
User Sub-menu 1.2 - Display Functions

These functions are used to choose the information to be displayed in operating mode:
• the measurement function (distance, level, volume, etc.) and units (mm, ft., m3, etc.)

• Display mode (1 (single) or 2 or more items in a repeating loop (cyclic mode))



Example procedure 2:
• to modify display mode from “single” to “cyclic” to configure a repeating loop displaying more

than one piece of data,

• to select Level and Distance and display each item for 5 seconds.


Step Action

Press buttons to
finish step

Information displayed at the end of
each step

1

Start from Operating Mode
screen

n/a

6750
LEVEL mm

2

Go to fct. 1.2.1 from the
operating mode

→,→,↑,→

Fct. 1.2.1
DISP.MODE

3 Enter

function

1.2.1

Display Mode (default
value: SINGL.MODE)

SINGL.MODE

4

Modify value to
CYCL.MODE

CYCL.MODE

5

Exit fct. 1.2.1data set field
and go to fct. 1.2.2

↵,↑

Fct.

1.2.2

DISPL.ITEM

6 Enter

function

1.2.2

(Display Item) data set field
Default value: LEVEL


LEVEL

7 Select

“DISTANCE”. ↑↑

DISTANCE

8

Press “RIGHT” to confirm
or cancel data item to be
added to display loop

No

9

Press “UP” to confirm
parameter

Yes

10

Exit data set field to
confirm. Go to to fct. 1.2.3

↵,↵,↑

Fct.

1.2.3

CYCLIC TIME

11

Enter function 1.2.3 data
set field (default value: 01).
Change to 05 seconds.

→,→,↑,↑,↑,↑

05

Sec

12

Exit data set field, function,
submenu and menu. Save
new configuration and
return to Operating Mode

↵,↵,↵,↵,↵

6750

LEVEL mm


The operator may display volume once the gauge is calibrated to measure volume in submenu
1.7. Interface parameters may only be used if the gauge is factory-set for interface measurement.

Advertising