SHIMPO DT-365 User Manual

Page 18

Advertising
background image

18

Phase mode

4.4.3

Delay emission can be set within the input signal range between 60 fpm and 10,000 fpm.
In the phase mode (PHA), the delay angle from the external pulse entry to strobe flash emission
can be changed by 0.1º using the dial within the range between 1º and 359º.
Press the UNIT key to set the phase change by time. The phase can be changed by 1 ms within
the range between 0 ms and 999 ms (max.).
When time is used for setting, a time longer than the emission cycle cannot be set.
Press the MODE key to switch to the emission count mode (FPM).

* When the external synchronous signal has not been entered, [ _ _ _ _ _ _ ] and the delay setting values

are indicated alternately.
When the external synchronous signal has been entered, only the delay setting value is indicated.

Operation

Display

Increase/decrease

the delay angle

Each press switches

the delay time

display

Delay angle: Decreases

Delay angle: Increases

Delay time: Decreases

Delay time: Increases

CCW

CW

CCW

CW

Press the key to

switch to the phase

mode

Phase mode

Emission count mode

Advertising
This manual is related to the following products: