SHIMPO DT-365 User Manual

Page 32

Advertising
background image

32

External pulse input

4.7.2

Connect the unit to external devices (sensors, etc.) to allow the strobe to emit light using the pulse
signal from those devices in the external trigger mode.
(For details, refer to 4.4 External synchronous emission)

Available input frequency

: Available measurement range 40 to 35,000fpm

Available delay emission range 60 to 10,000fpm

Available input pulse

: Hi 2.5 to 12V

: Lo 0 to 0.5V

Available input pulse width : 50 μs or more
Available delay setting angle : 0º to 359º, available to set by 1º
Available delay setting time : 0 to 999 (max.) ms, available to set by 1 ms

[Input circuit]

External

I/O connector

5pin
6pin

12V

Go to the input circuit

(insulated by photo coupler)

10kΩ

4.7k

10kΩ

12V

Switch in function mode 4

External trigger pulse output

4.7.3

Output the pulse to external devices simultaneously with emission while emission is performed in
the internal oscillation mode or external trigger mode.
A delay of approximately 30 μs caused by the internal circuit exists.

Output circuit specification : 12 V voltage output
Output pulse width

: Approx. 200 μs

[Output circuit]

[Output timing]

(36V)

External

I/O connector

3pin

4pin

12V

4.7kΩ

Emission

External

pulse output

Approx. 200 μs

Inside DT-361/365