West Control Solutions N8840 User Manual

Page 42

Advertising
background image

Configuration level

Configuration parameters

42

8840 profiler

Name

Value range Description

Default

m.Loc

Blockage of hand function

0

0

no function (switch-over via interface is possible)

2

DI1 switches

3

DI2 switches (only visible with OPTION)

4

DI3 switches (only visible with OPTION)

5

è - key switches

Err.r

Reset of all error list entries

0

0

no function (switch-over via interface is possible)

2

DI1 switches

3

DI2 switches (only visible with OPTION)

4

DI3 switches (only visible with OPTION)

5

è - key switches

6

Ò - key switches

Pid.2

Switching of parameter set (Pb, ti, td)

0

0

no function (switch-over via interface is possible)

2

DI1 switches

3

DI2 switches (only visible with OPTION)

4

DI3 switches (only visible with OPTION)

5

è - key switches

P.run

Programmer-Run/Stop (see Page 68)

0

0

no function

2

DI1 switches

3

DI2 switches (only visible with OPTION)

4

DI3 switches (only visible with OPTION)

P.off

Programmer off. Internal set-point is effective (see Page 68)

0

0

no function

2

DI1 switches

3

DI2 switches (only visible with OPTION)

4

DI3 switches (only visible with OPTION)

I.Chg

Switching of the actual process value between Inp1 and X2

0

0

no function (switch-over via interface is possible)

2

DI1 switches

3

DI2 switches (only visible with OPTION)

4

DI3 switches (only visible with OPTION)

5

è - key switches

di.Fn

Function of digital inputs (valid for all inputs)

0

0

direct

1

inverse

2

toggle key function

fDI1

Forcing di1 (only visible with 8800/8840 Configurator!)

0

0

No forcing

1

Forcing via serial interface

fDI2

Forcing di2 (only visible with 8800/8840 Configurator!)

0

0

No forcing

1

Forcing via serial interface