Chillers optichill, Sound data, Chillers – Airedale OptiChill FreeCool 500kW - 1365kW User Manual

Page 39

Advertising
background image

Chillers

OPTICHILL

Chillers

39

Technical Manual : 6530166 V1.6.0 02_2013

Sound Data

GLOBAL CHILLER SOUND LEVEL VALUES - HIGH EFFICIENCY PLUS

Standard D Models

Sound
Measurement

Overall

dB(A)

Frequency (Hz) dB

63

125

250

500

1000

2000

4000

OPC500HE+D8

Power

100

76

89

92

102

93

85

74

Pressure

@ 10m

68

44

57

60

70

61

53

42

OPC525HE+D10

Power

98

77

90

91

100

92

85

74

Pressure

@ 10m

66

45

58

59

68

60

53

42

OPC550HE+D10

Power

96

77

90

90

96

91

85

74

Pressure

@ 10m

64

45

58

58

64

59

53

42

OPC600HE+D10

Power

97

76

90

91

96

92

87

74

Pressure

@ 10m

65

44

58

59

64

60

55

42

OPC650HE+D10

Power

98

76

90

92

97

93

88

74

Pressure

@ 10m

66

44

58

60

65

61

56

42

OPC700HE+D12

Power

97

77

92

95

97

93

87

77

Pressure

@ 10m

64

44

59

62

64

60

54

44

OPC750HE+D12

Power

97

77

93

97

96

93

85

79

Pressure

@ 10m

64

44

60

64

63

60

52

46

OPC800HE+D14

Power

97

78

92

98

96

92

85

78

Pressure

@ 10m

64

45

59

65

63

59

52

45

OPC850HE+D14

Power

97

77

92

99

96

90

84

77

Pressure

@ 10m

64

44

59

66

63

57

51

44

OPC900HE+D16

Power

98

78

92

101

98

91

86

76

Pressure

@ 10m

65

45

59

68

65

58

53

43

OPC950HE+D18

Power

100

79

93

102

100

92

87

76

Pressure

@ 10m

67

46

60

69

67

59

54

43

OPC1000HE+D18

Power

99

79

93

102

99

93

87

77

Pressure

@ 10m

66

46

60

69

66

60

54

44

OPC1100HE+D18

Power

99

79

93

101

98

94

87

78

Pressure

@ 10m

66

46

60

68

65

61

54

45

Quiet DQ Models

Sound
Measurement

Overall

dB(A)

Frequency (Hz) dB

63

125

250

500

1000

2000

4000

OPC500HE+DQ12

Power

94

82

80

89

94

89

81

70

Pressure

@ 10m

61

49

47

56

61

56

48

37

OPC525HE+DQ12

Power

92

82

81

87

92

88

80

69

Pressure

@ 10m

59

49

48

54

59

55

47

36

OPC550HE+DQ12

Power

90

82

81

85

88

87

80

68

Pressure

@ 10m

57

49

48

52

55

54

47

35

OPC600HE+DQ12

Power

91

82

81

87

89

88

82

68

Pressure

@ 10m

58

49

48

54

56

55

49

35

OPC650HE+DQ12

Power

92

82

80

88

90

89

84

69

Pressure

@ 10m

59

49

47

55

57

56

51

36

OPC700HE+DQ14

Power

92

83

86

92

89

89

83

73

Pressure

@ 10m

59

50

53

59

56

56

50

40

OPC750HE+DQ16

Power

92

84

88

94

89

89

80

75

Pressure

@ 10m

59

51

55

61

56

56

47

42

OPC800HE+DQ16

Power

92

84

87

96

89

87

80

74

Pressure

@ 10m

59

51

54

63

56

54

47

41

OPC850HE+DQ18

Power

91

84

84

96

89

85

80

72

Pressure

@ 10m

58

51

51

63

56

52

47

39

OPC900HE+DQ20

Power

93

85

85

99

91

86

82

71

Pressure

@ 10m

60

52

52

66

58

53

49

38

OPC950HE+DQ20

Power

95

85

85

100

92

87

83

69

Pressure

@ 10m

62

52

52

67

59

54

50

36

OPC1000HE+DQ20

Power

94

85

86

99

91

89

83

72

Pressure

@ 10m

61

52

53

66

58

56

50

39

OPC1100HE+DQ20

Power

94

85

86

99

91

90

83

73

Pressure

@ 10m

61

52

53

66

58

57

50

40

1

dB(A) is the overall sound level, measured on the A scale.

2

All sound data measured at nominal conditions: Water in/out 12/7°C at 35°C ambient.

3

Based on standard unit, for units fitted with optional extras, please contact Airedale.

The Sound Pressure data quoted is only valid in free field conditions, where the unit is installed on a reflective base. If the equipment is
placed adjacent to a reflective wall, values may vary to those stated, typically increasing by 3dB for each side added.

Advertising
This manual is related to the following products: