Ultima compact chillers, Performance data – Airedale Ultima Compact FreeCool 30kW - 450kW User Manual

Page 26

Advertising
background image

ULTIMA COMPACT

Chillers

26

Chillers

Technical Manual : Part No 6259543 TM E_1.3.0 04/2013

Performance Data

SOUND DATA

Global Chiller Sound Level

Super Quiet - SSQ & DSQ Models

Sound Measurement

Overall

dB(A)

Frequency (Hz) dB

63

125

250

500

1000

2000

4000

UCC30SSQ-1/1
UCC30DSQ-1/1

Power

73

76

70

69

69

69

66

58

Pressure

@ 10m

41

44

38

37

37

37

34

26

UCC40SSQ-1/1
UCC40DSQ-1/1

Power

73

76

70

69

69

69

66

58

Pressure

@ 10m

41

44

38

37

37

37

34

26

UCC50SSQ-2/1
UCC50DSQ-2/1

Power

74

80

76

72

72

70

64

58

Pressure

@ 10m

42

48

44

40

40

38

32

26

UCC60SSQ-2/1
UCC60DSQ-2/1

Power

74

80

76

72

72

70

64

58

Pressure

@ 10m

42

48

44

40

40

38

32

26

UCC70SSQ-2/1
UCC70DSQ-2/1

Power

74

80

76

72

72

70

64

58

Pressure

@ 10m

42

48

44

40

40

38

32

26

UCC75DSQ-2/1

Power

73

76

80

76

67

68

62

53

Pressure

@ 10m

41

44

48

44

35

36

30

21

UCC80SSQ-2/1
UCC80DSQ-2/1

Power

75

74

73

73

72

71

68

61

Pressure

@ 10m

43

42

41

41

40

39

36

29

UCC100DSQ-3/1

Power

75

81

84

78

69

70

64

56

Pressure

@ 10m

43

49

52

46

37

38

32

24

UCC110DSQ-4/2

Power

77

82

84

76

74

73

67

61

Pressure

@ 10m

45

50

52

44

42

41

35

29

UCC125DSQ-4/1

Power

77

76

84

83

71

70

65

58

Pressure

@ 10m

45

44

52

51

39

38

33

26

UCC130DSQ-6/2

Power

80

80

84

82

76

75

69

63

Pressure

@ 10m

47

48

52

50

44

43

37

31

UCC150DSQ-4/1

Power

78

77

85

83

72

71

66

58

Pressure

@ 10m

46

45

53

51

40

39

34

26

UCC160DSQ-6/2

Power

80

80

84

82

76

75

69

63

Pressure

@ 10m

47

48

52

50

44

43

37

31

UCC180DSQ-6/2

Power

80

83

88

82

77

75

69

64

Pressure

@ 10m

48

51

56

50

45

43

37

32

UCC200DSQ-6/2

Power

81

81

87

85

78

75

69

64

Pressure

@ 10m

49

49

55

53

46

43

37

32

UCC225DSQ-8/2

Power

82

82

88

85

78

76

70

64

Pressure

@ 10m

50

50

56

53

46

44

38

32

UCC250DSQ-8/2

Power

82

82

88

85

78

76

70

64

Pressure

@ 10m

50

50

56

53

46

44

38

32

UCC275DSQ-10/2

Power

83

79

85

82

81

77

75

70

Pressure

@ 10m

51

47

53

50

49

45

43

38

UCC300DSQ-12/2

Power

83

80

85

83

81

77

75

70

Pressure

@ 10m

51

48

53

51

49

45

43

38

UCC330DSQ-14/2

Power

84

81

87

84

82

78

74

68

Pressure

@ 10m

51

48

54

51

49

45

41

35

UCC360DSQ-14/2

Power

84

81

87

84

83

79

74

67

Pressure

@ 10m

51

48

54

51

50

46

41

34

UCC400DSQ-16/2

Power

85

82

88

85

83

79

76

71

Pressure

@ 10m

52

49

55

52

50

46

43

38

UCC450DSQ-16/2

Power

86

82

88

85

84

80

78

72

Pressure

@ 10m

53

49

55

52

51

47

45

39

1

dB(A) is the overall sound level, measured on the A scale.

2

All sound data measured at nominal conditions: Water in/out 12/7°C at 30°C ambient.

3

Figures based on standard unit, for units fitted with optional pump packages, please contact Airedale.

The Sound Pressure data quoted is only valid in free field conditions, where the unit is installed on a reflective base. If
the equipment is placed adjacent to a reflective wall, values may vary to those stated, typically increasing by 3dB for
each side added.

Advertising