General Specification

ELECTRICAL DATA

UCC160D-4/2

UCC180D-6/2

UCC200D-6/2

UCC225D-6/2

UCC250D-6/2

UCC275D-8/2

Unit Data

Nominal Run Amps

(1) A

99

115

127

137

149

160

Maximum Start Amps

(2) A

252

281

342

373

386

440

Permanent Supply

VAC

230 V 1 PH 50 Hz

Mains Supply

VAC

400 V 3 PH 50 Hz

Rec Permanent Fuse Size

A

16

16

16

16

16

16

Rec Mains Fuse Size

A

125

160

160

200

200

200

Max Permanent Incoming Cable Size

mm²

4 mm² terminals

Max Mains Incoming Cable Size

mm²

Direct to Bus Bar

Control Circuit

VAC

24V/230V AC

Evaporator

Pad Heater Rating

W

100

100

100

100

100

100

External Trace Heating

Available (fitted by others)

W

500

500

500

500

500

500

Condenser Fan - Per Fan

Quantity

4

6

6

6

6

8

Full Load Amps

A

2.70

2.70

2.70

2.70

2.70

1.75

Locked Rotor Amps

A

7.00

7.00

7.00

7.00

7.00

6.20

Motor Rating

kW

1.75

1.75

1.75

1.75

1.75

1.75

Compressor - Per Compressor

Quantity

4

2 + 2

2 + 2

2 + 2

4

2 + 2

Motor Rating

kW

11.7

15.0 / 11.7

18.2 / 11.7

18.2 / 15.0

18.2

22.8 / 18.2

Nominal Run Amps

(1) A

22.0

27.0 / 22.0

33.0 / 22.0

33.0 / 27.0

33.0

40.0 / 33.0

Sump Heater Rating

W

75.0

130.0 / 75.0

130.0 / 75.0

130.0 / 130.0

130.0

130.0 / 130.0

Start Amps

(2)

175.0

215.0 / 175.0

270.0 / 175.0

270.0 / 215.0

270.0

320.0 / 270.0

Type Of Start

Direct on line

QUIET DQ

UCC160DQ-6/2

UCC180DQ-6/2

UCC200DQ-6/2

UCC225DQ-8/2

UCC250DQ-8/2

UCC275DQ-8/2

All data as above except:

Condenser Fan - Per Fan

Quantity

6

6

6

8

8

8

Full Load Amps

A

1.25

1.25

1.25

1.25

1.25

1.15

Locked Rotor Amps

A

4.50

4.50

4.50

4.50

4.50

2.10

Motor Rating

kW

0.69

0.69

0.69

0.69

0.69

0.70

SUPER QUIET DSQ

UCC160DSQ-6/2

UCC180DSQ-6/2

UCC200DSQ-6/2

UCC225DSQ-8/2

UCC250DSQ-8/2

UCC275DSQ-10/2

All data as above except:

Condenser Fan - Per Fan

Quantity

6

6

6

8

8

10

Full Load Amps

A

0.78

0.78

0.78

0.78

0.78

0.83

Locked Rotor Amps

A

1.50

1.50

1.50

1.50

1.50

1.50

Motor Rating

kW

0.48

0.48

0.48

0.48

0.48

0.32

OPTIONAL EXTRAS

Power Factor Correction

Nominal Run Amps

(1) A

91

105

117

125

137

146

Maximum Start Amps

(2) A

252

281

342

373

386

430

Recommended Mains Fuse

A

125

125

160

160

200

200

Compressor Nominal Run Amps
- Per Compressor

A

4 x 20

2 x 24/2 x 20

2 x 30/2 x 20

2 x 30/2 x 24

4 x 30

2 x 36 / 2 x 30

Electronic Soft-start

Nominal Run Amps

(1) A

99

115

127

137

149

160

Maximum Start Amps

(2) A

182

198

234

239

278

302

Recommended Mains Fuse

A

125

160

160

200

200

200

Single Head Pump (or Run/Standby)

Unit Nominal Run Amps

(1) A

105

120

132

141

154

173

Recommended Mains Fuse

A

125

160

160

200

200

200

Motor Rating

kW

3.0

3.0

3.0

3.0

3.0

5.5

Full Load Amps

A

6.1

6.1

6.1

6.1

6.1

11.7

Larger Single Head Pump (or Run/Standby)

Unit Nominal Run Amps

(1) A

107

122

134

144

156

183

Recommended Mains Fuse

A

125

160

160

200

200

250

Motor Rating

kW

4.0

4.0

4.0

4.0

4.0

11.0

Full Load Amps

A

7.7

7.7

7.7

7.7

7.7

21.5

Twin Head Pump

Unit Nominal Run Amps

(1) A

107

122

134

144

156

171

Recommended Mains Fuse

A

125

160

160

200

200

200

Motor Rating

kW

4.0

4.0

4.0

4.0

4.0

5.5

Full Load Amps

A

7.7

7.7

7.7

7.7

7.7

11.7

Larger Twin Head Pump

Unit Nominal Run Amps

(1) A

110

125

137

147

159

183

Recommended Mains Fuse

A

125

160

160

200

200

250

Motor Rating

kW

5.5

5.5

5.5

5.5

5.5

11.0

Full Load Amps

A

11.1

11.1

11.1

11.1

11.1

21.5

(1)

Based at 12/7°C water and 30°C ambient

(2)

Starting amps refers to the direct on line connections.