Features, Chill ers, Ultima com pact – Airedale Ultima Compact FreeCool 30kW - 450kW User Manual
Page 5
Te
c
h
n
ic
a
l M
a
n
u
a
l :
Pa
rt
No
6
2
5
9
5
4
3
T
M
E
_
1
.3
.0
0
4
/2
0
1
3
Ch
ille
rs
5
Chill
ers
ULTIMA
COM
PACT
FEATURES
UCC30, UCC40,
UCC50, UCC60, UCC70
& UCC80
UCC75, UCC100,
UCC125 &
UCC150
UCC110,
UCC130, UCC160
& UCC180
UCC200, UCC225
& UCC250
UCC275, UCC300,
UCC330, UCC360,
UCC400 & UCC450
Construction
4 x eye bolts to BS4278 or Integrated lugs/Mounting feet
Integrated lugs
Lifting Eye Bolts
Lifting Eye Bolts
Lifting Eye Bolts
Lifting Eye Bolts
Acoustically lined compressor enclosure
SSQ/DSQ Models
DSQ Models
DSQ Models
DSQ Models
DSQ Models
Refrigeration
Full Operating Charge of R407C
Std
Std
Std
Std
Std
Number of Independent Refrigeration Circuits
1 or 2
2
2
2
2
Scroll Compressor Arrangement
1 x Tandem Set
or 2 x Single
2 x Tandem Sets
2 x Tandem Sets
2 x Tandem Sets
2 x Tandem Sets
(UCC275-300)
2 x Trio Sets
(UCC330-450)
Plate Evaporator
Std
Std
Std
Std
Std
Enhanced Refrigeration Condenser Coils
SSQ/DSQ Models
DSQ Models
DSQ Models
DSQ Models
DSQ Models
Sickle Bladed Fans
-
Long Bellmouth
Long Bellmouth
Long Bellmouth
Long Bellmouth
Low speed condenser fan
SQ/DQ Models
DQ Models
DQ Models
DQ Models
DQ Models
Extra Low speed condenser fan
SSQ/DSQ Models
DSQ Models
DSQ Models
DSQ Models
DSQ Models
Thermostatic Expansion valve & Liquid line solenoid valve
Std
Std
Std
Std
-
Electronic Expansion Valve
Opt (SQ/DQ Models)
Opt (SSQ/DSQ Models)
DQ/DSQ Models
Opt (D Models)
DQ/DSQ Models
Opt (D Models)
DQ/DSQ Models
Opt (D Models)
Std
Water Inlet/Outlet
Threaded BSP female
Flanged PN16
Flanged PN16
Flanged PN16
Flanged PN16
Liquid line sight glass
Std
Std
Std
Std
Std
Liquid and Discharge line ball valve
Opt
Std
Std
Std
Std
Large capacity filter drier
Fixed Cores
Replaceable Cores
Replaceable Cores
Replaceable Cores
Replaceable Cores
Manual reset HP/LP Switch (LP via microprocessor)
Std
Std
Std
Std
Std
Suction and liquid pressure transducers
Std
Std
Std
Std
Std
Compressor minimum differential pressure protection
Std
Std
Std
Std
Std
Pressure relief valve, integral rupture disc & gauge
Std
Std
Std
Std
Std
Electrical
AireTronix Microprocessor Controller
Std
Std
Std
Std
Std
Modulating Head Pressure Control
Std
Std
Std
Std
Std
Emergency stop
-
Std
Std
Std
Std
Individual door isolated mains power compartments for
each refrigeration CCT, fans & pump option
-
-
Std
Std
Std
Dedicated bus-bar chamber for incoming 3-phase & earth
mains power supply (no neutral required)
-
-
Std
Std
Std
Evaporator Pad Heater
Std
Std
Std
Std
Std
Trace Heating to Internal Pipework
Std
Std
Std
Std
Std
Connections for External Trace Heating
Std
Std
Std
Std
Std
Phase Rotation Protection
Opt
Opt
Opt
Std
Opt
Power Factor Correction
-
Opt
Opt
Opt
Opt