Advanced configuration

Before you specify input for a hardware device, verify the hardware device recognizes sensor
operation. Most hardware devices can show this in their configuration interfaces, or via CGI script
commands. Also check the release notes to verify that input-controlled operation is supported for the
hardware device and firmware used.

To add and/or configure a hardware input event, do the following:

1. In the Management Application navigation pane, expand Advanced Configuration, then

expand Events and Output. Right-click Hardware Input Events and select Enable New
Input Event
.

2. In the Hardware Input Event Properties window's list of hardware devices, expand the

required hardware device to see a list of pre-defined hardware input.

3. Select the required types of input to use them as events. The types of input often vary from

camera to camera. If motion detection (see "Motion detection & exclude regions" on page 95)
is enabled in Milestone Husky product for the camera in question, note the input type System
Motion Detection
, which lets you turn detected motion in the camera's video stream into an
event. In earlier Milestone Husky product versions, this was known as a VMD event.

Note that some types of input are mutually exclusive. When you select one type of input, you
may therefore note that other types of input become unavailable for selection.

4. For each selected type of input, select required properties (see "Hardware input event" on

page 118). When ready, click OK, or click the Add button to add a timer event (on page 113)
to the event you have just created.

5. Save your configuration changes by clicking Save in the yellow notification bar in the upper-

right corner of the Management Application.

Add a hardware output

With hardware output, you can add external output units, such as lights, sirens, door openers, etc., to
your Milestone Husky product system. Once added, output can be activated automatically by events or
detected motion, or manually by client users.

Before you specify output, verify that sensor operation is recognized by the hardware device with
which you are going to use the output. Most hardware devices are capable of showing this in their
configuration interfaces, or via CGI script commands. Also check the release notes to verify that
output-controlled operation is supported for the hardware device and firmware used.

To add a hardware output event, do the following:

1. Expand Advanced Configuration, then expand Events and Output. Right-click Hardware

Output and select Add New Output.

2. In the Hardware Output Properties window's list of hardware devices, select the required

hardware device, and click the Add button below the list.

3. Specify required properties (see "Hardware input event" on page 118).

4. Click OK.

5. Save your configuration changes by clicking Save in the yellow notification bar in the upper-

right corner of the Management Application.