Introduction

Example: The Milestone Mobile server is installed on a server with the IP address 127.2.3.4
and is configured to accept HTTP connections on port 8081 and HTTPS connections on port
8082 (default settings of the installer).

In the address bar of your browser, type:

http://127.2.3.4:8081/XProtectMobile/Web/

or

https://127.2.3.4:8082/XProtectMobile/Web/

, depending on whether you want to use a

standard HTTP connection or a secure HTTPS connection. You can now begin using XProtect
Web Client.

4. Add the address as a bookmark in your browser for easy future access to XProtect Web

Client. If you use XProtect Web Client on the local computer on which you installed the
Milestone Mobile server, you can also use the desktop shortcut created by the installer. Click
the shortcut to launch your default browser and open XProtect Web Client.

Note that Internet browsers running the XProtect Web Client must have their cache cleared before you
can use a new version of the XProtect Web Client.

System administrators must ask their XProtect Web Client users to clear out their browser's cache
upon upgrade or force this action remotely (you can do this action only in Internet Explorer in a
domain).

Recording Server Manager

The Recording Server service is a vital part of the surveillance system. Video streams are only
transferred to your system while the Recording Server service is running. The Recording Server
Manager informs you about the state of the Recording Server service. It also lets you manage the
service.

In the notification area (the system tray), the Recording Server Manager's icon indicates whether the
Recording Server service is running or not.

- A green icon in the notification area indicates that the Recording Server service is running.

- A red icon in the notification area indicates that the Recording Server service has stopped.

By right-clicking the icon, you can open the Management Application, start and stop the Recording
Server service, view log files, and view version information.

Monitor System Status

Right-click the notification area's Recording Server icon and select Show System Status to get
access to the Status window.

The Status window lets you view the status of the image server(s) and connected cameras. The
status of each server/camera is indicated by a color:

Green indicates that the server or camera is running correctly.

Gray indicates that the camera (not the server) is not running. Typically, a camera is indicated
in gray in the following situations:

o

The camera is not online (as defined in the camera's online period schedule (see "Online
period"
on page 135)).

o

The Recording Server service has been stopped.