HP XP P9500 Storage User Manual

Page 216

Advertising
background image

Setting

Available operation

Result of operation

AFB

IEM

When a path is not being monitored,

the IEM settings will take effect

again when the path is recovered

from the error status by performing

an automatic failback.

Set IEM to off.

IEM is disabled.

The error count, elapsed monitoring

time, and information about paths

not subject to automatic failbacks

are cleared.

off

Set AFB to on.

The operations of AFB and IEM do not

change.

Change the AFB setting.

AFB operates using new settings.

Set AFB to off.

AFB is disabled.

Set IEM to on.

IEM is enabled.

#1

off

on

#2

Set AFB to on.

AFB and IEM are enabled.

#1

Set AFB to off.

The operations of AFB and IEM do not

change.

off

Set AFB to on.

AFB is enabled.

Set AFB to off.

The operations of AFB and IEM do not

change.

Legend:

AFB: Automatic failback
IEM: Intermittent error monitoring

#1

When this condition is not satisfied, the KAPL01080-W message is output

and an error occurs. The status of intermittent error monitoring does not

change.

#2

Because automatic failback is off, intermittent error monitoring is

disabled.

Example

The following example shows how to enable monitoring of intermittent

errors:

PROMPT>dlnkmgr set -iem on -intvl 20 -iemnum 2

KAPL01049-I Would you like to execute the operation?

Operation name = set [y/n]: y

KAPL01001-I The HDLM command completed normally. Operation

name = set, completion time = yyyy/mm/dd hh:mm:ss

PROMPT>