Notes on creating an hdlm environment, Notes on hbas and hba drivers, Notes on storage systems – HP XP P9500 Storage User Manual

Page 83: Notes on hdlm versions, Notes on creating an hdlm environment -15, Notes on hbas and hba drivers -15, Notes on storage systems -15, Notes on hdlm versions -15

Advertising
background image

Notes on Creating an HDLM Environment

This section provides notes on creating an HDLM environment.

For details about operating HDLM, see

Notes on Using HDLM on page 4-2

.

Notes on HBAs and HBA Drivers

If you are using the Storport Miniport driver as an HBA driver in Windows

Server 2003, install QFE 838894 or later for the Microsoft Storport driver

or install Windows Server 2003 SP1 or later, before installing HDLM.

If you are using multiple HBAs, make sure that the models of the HBAs

are the same. Also make sure that the HBA firmware versions and driver

versions are the same.

Notes on Storage systems

You must not change the vendor ID and product ID of the storage

system. If you change these IDs, HDLM will not be able to recognize the

storage system.

If the host and the storage system are connected via a Fibre Channel

switch, select Point To Point as the connection type. If you select FC-AL

(Fibre Channel Arbitrated Loop) as the connection type, an unexpected

path error might occur.

Windows can recognize LUNs from 0 to 255. Therefore, set LUNs within

the range from 0 to 255 in the storage system management software.

Notes on HDLM Versions

If HDLM 5.4 or earlier has been installed, remove HDLM first and then

proceed with a new installation of HDLM by following the procedure

described in

Migrating from HDLM 5.4 or Earlier to HDLM 5.5 or Later on

page 3-65

.

For HDLM 5.6 or later, the trace files for HDLM versions earlier than 5.6

are divided into integrated trace files and trace files. The logs for the

HDLM commands and HDLM GUI operations are output to integrated trace

files. Trace information for the HDLM manager is output to trace files. The

output destinations for the files are changed as follows:

¢

When you migrate from an HDLM version earlier than 04-00 to an

HDLM version 5.6 or later
- Trace files before migration:

drive-for-program-installation:\Program Files

#

\HITACHI\HNTRLib

\spool\hntrn.log

(n indicates a file number)
- Integrated trace files after migration:

drive-for-program-installation:\Program Files

#

\HITACHI

\HNTRLib2\spool\hntr2n.log

(n indicates a file number)

Creating an HDLM Environment

3-15

Hitachi Dynamic Link Manager User Guide for Windows

®

Advertising