Upgrade installation or re-installation of hdlm, Upgrade – HP XP P9500 Storage User Manual

Page 132

Advertising
background image

27

.

Connect cables to all the HBAs to change the configuration to a multi-path

configuration.

28

.

Check the path information as described in

Checking the Path

Configuration on page 3-69

to make sure that you have successfully

assembled a multi-path configuration.

Upgrade Installation or Re-installation of HDLM

You can perform an upgrade installation for only HDLM 5.5 or later. To

migrate HDLM 5.4 or earlier to version 5.5 or later, see

Migrating from HDLM

5.4 or Earlier to HDLM 5.5 or Later on page 3-65

.

The procedure for an upgrade installation or re-installation is the same as for

a new installation of HDLM, with the exception of the following steps:

Executing the dlmchkpath utility to check the HDLM paths.
The dlmchkpath utility is executed automatically when the installation

program (setup.exe) starts. The dlmchkpath utility checks whether the

system is in a single-path or multi-path configuration. If a warning dialog

box appears in a Windows Server 2003 environment in which no service

packs are installed, return everything to a single-path configuration, and

then upgrade or reinstall HDLM. Note, however, that when an unattended

installation is used and the system is determined to be in a multi-path

configuration, an HDLM upgrade installation or re-installation will end and

no warning dialog boxes will be displayed.
For details about the dlmchkpath utility, see

The dlmchkpath Utility for

Checking HDLM Paths on page 7-14

.

Entering the license key
The window displays the type and expiration date of the license key,

which were both entered when HDLM was installed for the first time. If

the license key has expired, the procedure is the same as for a new

installation.

Checking the PRSV key
If an appropriate PRSV key exists, you do not need to check for duplicate

PRSV keys after the installation finishes.

If you only upgrade or reinstall HDLM, you do not need to change the

storage system settings. If you upgrade or reinstall HDLM after changes

are made to system configurations, such as adding storage systems and

changing path configurations, revise the settings accordingly.

By default, if you upgrade HDLM from version 6.3 or later in Windows

Server 2003, the MPIO driver is not upgraded. As a result, the

KAPL09281-I message reports that the MPIO driver will not be

overwritten. If you want to repair the MPIO driver by overwriting it, select

the Re-install MPIO drivercheck box.

Upgrade installation or re-installation from HDLM 5.7 or later

¢

Selecting an HDLM management-target device
The default of the HDLM management-target device is the same as

that before the upgrade installation or re-installation. For example, if

3-64

Creating an HDLM Environment

Hitachi Dynamic Link Manager User Guide for Windows

®