Parameter

-r [PRSV-key-to-be-specified-by-user][-s]

Specify this parameter when you register a PRSV key.

PRSV-key-to-be-specified-by-user

A maximum of 16 hexadecimal digits can be specified.

If this parameter is omitted, or the dlmprsvkey utility is

automatically executed during HDLM installation:
The dlmprsvkey utility for registering an HDLM persistent

reservation key creates a PRSV key by using the MAC address of

the NIC and the execution time of the utility. If the MAC address

of the NIC cannot be obtained, the dlmprsvkey utility creates a

PRSV key by using the execution time of the utility only.

If this parameter is specified:
If less than 16 digits are specified, zeros will be added to the left

of the entered value to make it 16 digits. The specified value must

satisfy both of the following conditions:
- Must be a unique value among all the hosts in the SAN.
- Specifiable values are single-byte characters from 0 to 9, a to f,

and A to F. Values cannot be specified using zeroes only.

Example

In the following example, the utility registers the PRSV key without

specifying it on the host:

PROMPT>dlmprsvkey -r

KAPL12104-I The operation for PRSV key registration will now

start. Is this OK? [y/n]: y

KAPL12106-I An attempt to register the PRSV key was

successful. (PRSV key = 0123456789abcdef)

PROMPT>

In the following example, the utility registers the PRSV key by

specifying it on the host:

PROMPT>dlmprsvkey -r 0123456789ABCDEF

KAPL12104-I The operation for PRSV key registration will now

start. Is this OK? [y/n]: y

KAPL12106-I An attempt to register the PRSV key was

successful. (PRSV key = 0123456789abcdef)

PROMPT>

-s

Specify this parameter to avoid displaying a confirmation message

upon execution of the dlmprsvkey utility.

-v

Specify this parameter to display the registered PRSV key.

Example

PROMPT>dlmprsvkey -v

KAPL12116-I The registered PRSV key will now be displayed.

(PRSV key = 0123456789abcdef)

PROMPT>

Utility Reference

7-13

Hitachi Dynamic Link Manager User Guide for Windows

®