5157/5157 ACL S-Series DLT Subsystems installation Users Guide


Installing and Configuring the 5157 ACL Tape Subsystem

5-4

5.3.1 Setting the SCSI ID

1. Turn the 5157 ACL on. Wait until the Power-On Self Test

terminates and the default screen appears on the display. Figure
5-3 shows the default screen for the unit. This figure shows a
magazine with only one cartridge, in slot 1. There will be
rectangles on line three on the default screen in positions that
correspond to the slots where cartridges are present.





Figure 5-3 Default Screen

2. At the Default Screen, press the Enter button. The display will

show the Main Menu, as in Figure 5-4.

ч

ч

Load/Unload

Unlock Door
Show Status Menu
Maintenance Menu

ê

Figure 5-4 Main Menu

3. Press the

ü button four times to move the ÷ to Configure

Menu, then press the Enter button. The display will show the
Configure submenu, as shown in Figure 5-5. Note that the

ê at

the end of the fourth line means there are additional
configuration options that can be reached by scrolling with the
ü button.


DLT1 No Tape

DLT1 No Tape

Load

Load

e

r Idle

r Idle

1

1

F

F

_ _ _ _ _ _ _

_ _ _ _ _ _ _

E

E

10

10