5157/5157 ACL S-Series DLT Subsystems installation Users Guide


Installing and Configuring the 5157 ACL Tape Subsystem

5-6

5. Note that the Library SCSI ID is set to 3. If the DLT1 bus ID needs to

be set to 5, make sure the

÷ is next to line 1, and press the ü button

repeatedly until the display scrolls as shown in Figure 5-7.

Library Bus ID:

й

*3

ч

ч

DLT1 Bus ID:

*

5

Figure 5-7 Set SCSI Submenu Scrolled

NOTE: If the drive is being daisy chained, the drive ID must be changed
to ID 4. The library needs to be set to ID 2 to avoid SCSI conflicts.

6. With the

÷ next to line 3, press the Enter button. The ÷ moves to line

4, the

é appears at the end of line 1, and the ê appears at the end of

line 4. Use the

ù and ü buttons to scroll line 4 to display the possible

settings. Scroll so that 5 is displayed, then press the Enter button to
save the new selection. An * appears at the left of the 5 to indicate that
it is the current selection.


7. Press the Escape button repeatedly until the submenu in Figure 5-5

re-appears.


8. Repeat this procedure for each configuration option that needs to be

change.