Managing H3C LSW1FC4P0 Interface Card

Displaying Interface Card Information

59273-00 C

15

Temperature Failure Port
Shutdown

Non-configurable (always enabled for this H3C
LSW1FC4P0 Interface Card). All ports are downed when
the H3C LSW1FC4P0 Interface Card temperature
exceeds the Failure Temperature.

ASIC Temperature

Temperature of the ASIC

ASIC Warning Tempera-
ture

Non-configurable temperature threshold (102° Celsius)
above which a warning condition alarm is generated.

ASIC Failure Temperature

Non-configurable temperature threshold (105° Celsius)
above which a failure condition alarm is generated.

Board Temperature

Temperature of the Board

Board Warning Tempera-
ture

Non-configurable temperature threshold (75° Celsius)
above which a warning condition alarm is generated.

Board Failure Temperature

Non-configurable temperature threshold (81° Celsius)
above which a failure condition alarm is generated.

POST Status

Status from the most recent Power On Self Test

POST Fault Code

Fault code from the most recent Power On Self Test

Test Status

The current diagnostic test status of the H3C
LSW1FC4P0 Interface Card.

Test Fault Code

The code value for the last recorded diagnostic test status
recorded on the H3C LSW1FC4P0 Interface Card.

Network Group

IPv4 Enabled

Internet Protocol version 4 Enabled status

IPv4 Address

Mask that determines the IP address subnet

IPv4 Subnet Mask

Mask that determines the IP address subnet

IPv4 Gateway

IPV4 gateway address

IPv6 Enabled

Internet Protocol version 6 Enabled status

IPv6 Address

Mask that determines the IP address subnet

IPv6 Gateway

IPV6 gateway address

CPU0 MAC Address

N/A - does not apply to this switch

CPU1 MAC Address

N/A - does not apply to this switch

SNMP Enabled

SNMP enabled or disabled

Table 2-3. Switch Data Window Entries (Continued)

Entry

Description

Advertising