Managing Ports

Port Statistics Data Windows

59273-00 C

65

Bad Frames

Number of frames that were truncated due to a loss of sync or
the frame didn't end with an EOF.

BB_CreditRecoveryFr
ameFailure

Number of times more frames were lost during a credit
recovery period than the recovery process could resolve. This
causes a Link Reset to recover the credits.

BB_CreditRecoveryR
RDYFailure

Number of times more R_RDYs were lost during a credit
recovery period than the recovery process could resolve. This
causes a Link Reset to recover the credits.

Class 2 Frames In

Number of class 2 frames received by this port.

Class 2 Frames Out

Number of class 2 frames transmitted by this port.

Class 2 Words In

Number of class 2 words received by this port.

Class 2 Words Out

Number of class 2 words transmitted by this port.

Class 3 Frames In

Number of class 3 frames received by this port.

Class 3 Frames Out

Number of class 3 frames transmitted by this port.

Class 3 Toss

N/A - does not apply to this switch.

Class 3 Words In

Number of class 3 words received by this port.

Class 3 Words Out

Number of class 3 words transmitted by this port.

Decode Errors

Number of invalid transmission words detected during decod-
ing. Decoding is from the 10-bit characters and special K char-
acters.

Ep Connects

Number of E_Port logins.

FBusy

Number of class 2 and class 3 fabric busy (F_BSY) frames
generated by this port in response to incoming frames. This
usually indicates a busy condition on the fabric or N_port that
is preventing delivery of this frame.

Flow Errors

Number of times a frame is received and all the H3C
LSW1FC4P0 Interface Card ports receive buffers are full. The
normal Fabric Login exchange of flow control credit should
prevent this from occurring. The frame will be discarded.

FReject

Number of frames, from devices, that have been rejected.
Frames can be rejected for any of a large number of reasons.

Invalid CRC

Number of invalid Cyclic Redundancy Check (CRC) frames
detected.

Table 3-15. FC Port Statistics Data Window Entries (Continued)

Entry

Description

Advertising