Configuring port threshold alarms, Port threshold alarm configuration dialog – HP Switch SFP Modules User Manual

Page 33

Advertising
background image

Managing H3C LSW1FC4P0 Interface Card

Configuring Port Threshold Alarms

59273-00 C

23

Configuring Port Threshold Alarms

You can configure the interface card to generate alarms for selected events.
Configuring an alarm involves choosing an event type, rising and falling triggers, a
sample window, and finally enabling or disabling the alarm. To configure port
threshold alarms, do the following:

1.

In the faceplate display, open the Switch menu and select Port Threshold
Alarm Configuration
. The Port Threshold Alarm Configuration dialog
(

Figure 2-12

) prompts you to enable or disable all alarms, select an event,

set triggers, set a sample window and enable or disable an individual alarm.

Figure 2-12 Port Threshold Alarm Configuration Dialog

2.

Select the Enable All Port Threshold Alarms option to enable monitoring
for all the individual alarm types that are enabled. The Enable All Port
Threshold Alarms
option is the master control for the individual alarms. For
example, the switch will monitor CRC errors only if both the CRC Error
Enable and Enable All Port Threshold Alarms options are selected.

3.

Select an event type from the Port Threshold Alarm drop-down list. Choose
from the following options:

CRC error monitoring

Decode error monitoring

ISL monitoring

Login monitoring

Logout monitoring

Loss of signal monitoring

4.

Select the Enable option to make the alarm eligible for use.