When mscs is used -56 – HP XP7 Storage User Manual

Page 124

Advertising
background image

HDLM Manager Ver WakeupTime

Alive x.x.x-xx yyyy/mm/dd hh:mm:ss

HDLM Alert Driver Ver WakeupTime ElogMem Size

Alive x.x.x-xx yyyy/mm/dd hh:mm:ss 128

HDLM Driver Ver WakeupTime

Alive x.x.x-xx yyyy/mm/dd hh:mm:ss

License Type Expiration

Permanent -

KAPL01001-I The HDLM command completed normally. Operation name

= view, completion time = yyyy/mm/dd hh:mm:ss

PROMPT>

21

.

Use the results of the view operation to check the version of the installed

HDLM.
If x.x.x-xx is displayed in HDLM Version, the correct version of HDLM

has been installed.

22

.

Use the results of the view operation to check that the programs are

running properly.
If HDLM Manager, HDLM Alert Driver, and HDLM Driver are all Alive, all

the programs are running correctly.

23

.

Check the path information as described in

Checking the Path

Configuration on page 3-70

, and make sure that you have successfully

installed HDLM in a single-path configuration.

24

.

Connect cables to all the HBAs to change the configuration to a multi-path

configuration.
The following figure shows a single path configuration and a multi-path

configuration.

Figure 3-4 Single Path Configuration and Multi-path Configuration

25

.

Check the path information as described in

Checking the Path

Configuration on page 3-70

to make sure that you have successfully

assembled a multi-path configuration.

When MSCS Is Used

The following provides explanations of how to install MSCS before and after

an HDLM installation.

3-56

Creating an HDLM Environment

Hitachi Dynamic Link Manager (for Windows®) User Guide