completes. When intermittent error monitoring is not being

performed, the number of errors that determine that an intermittent

error has occurred is not counted and this value is not changed.
The number of times that the error is to occur is stored in the system,

even when -iem off is specified and intermittent error monitoring is

disabled. Therefore, when you re-enable intermittent error monitoring

without specifying the number of times, the error monitoring will be

executed using the value stored in the system.

When the set -iem on operation is executed during error monitoring,

even if you do not change the conditions for intermittent error

monitoring, the number of errors and the time that has passed since the

error monitoring has started are reset to 0. Intermittent error monitoring

will then resume with the changed settings.
If you set the automatic failback function to off while intermittent error

monitoring is on, intermittent error monitoring will be disabled. Note,

however, that if you use the view -sys operation to display the HDLM

functionality configuration, Intermittent Error Monitor will be shown as
on. When the automatic failback function is returned to on, intermittent

error monitoring will once again be enabled.
The executable operations for the automatic failback function and

intermittent error monitoring depend on the settings for those functions.

The table below shows the relationship between the settings and available

operations for automatic failback and intermittent error monitoring.

Table 6-5 Relationship Between the Setting for the Automatic Failback

Function and Intermittent Error Monitoring and the Executable Operations

Setting

Available operation

Result of operation

AFB

IEM

on

on

Set AFB to on.

The operations of AFB and IEM do not

change.

Change the AFB setting.

AFB is performed under the new
settings.

#1

Set AFB to off.

AFB and IEM are disabled.

The error count, elapsed monitoring

time, and information about paths

not subject to automatic failback are

cleared.

Set IEM to on.

When a path is being monitored

(during a period of conditional

intermittent error monitoring), the

value of the error count and the

elapsed monitoring time are reset to
0, and then intermittent error

monitoring will restart.

When a path is not being monitored,

nothing changes.

Command Reference