background image

Displayed Item

Description

No

summary

displayed

Summary

displayed

check the status of individual paths and resolve the problem

for any paths that have an error status.

PathStatus

Status of the displayed paths. The displayed status indicates

the following:

Online: All paths are available.

Reduced: Some paths are not available.

Reduced means that some paths might have an error status, in

which case you should check the status of individual paths and

resolve the problem for any paths that have an error status.

IO-Count

Total I/O count for all the displayed paths, indicated by a

decimal number. The maximum value that can be displayed is
2

32

- 1 (4294967295). If the total I/O count reaches the

maximum value, it will re-start from 0.

IO-Errors

Total I/O error count for all the displayed paths, indicated by a

decimal number. The maximum value that can be displayed is
2

32

- 1 (4294967295). If the total I/O error count reaches the

maximum value, it will re-start from 0.

PathID

The AutoPATH_ID indicated by a decimal number.
The AutoPATH_ID is assigned every time the host is restarted.

PathName

#

1

-

The path name, which indicates a path. When you modify the

system configuration or replace a hardware item, you should

check the path names to identify the physical path that will be

affected by the change. Path name consists of the following

four elements, separated by periods:

Host port number (hexadecimal number)

Bus number (hexadecimal number)

Target ID (hexadecimal number)

Host LU number (hexadecimal number)

For details about each element of the path name and its

representation in Windows, see

Table 6-15 Elements of a Path

Name on page 6-58

.

DskName

#1

DskName

The storage system name, which identifies the storage system

that is accessed by a path.
A storage system name consists of the following three

elements, separated by periods:

Vendor ID: The name of the storage system vendor (for

example, HITACHI).

Product ID: Indicates the storage system product ID,

emulation type, or model ID (for example, DF600F).
For more details, see

Table 6-16 Product ID Displayed by

the View -path Operation on page 6-58

.

Serial number: For the Thunder 9500V series, Lightning

9900V series, Hitachi USP series, Hitachi

AMS2000/AMS/WMS/SMS series, HUS100 series, Universal

6-52