When a value of 2 or more is specified for the number of times, the

following condition must be satisfied:

error-monitoring-interval >= checking-interval-for-automatic-

failback x number-of-times-error-is-to-occur-during-intermittent-

error-monitoring

If this condition is not satisfied, the KAPL01080-W message will be output

and an error will occur. If this happens, change any of the following

settings: the checking interval for automatic failback, intermittent error

monitoring interval, or the number of times that the error is to occur.
When you set the number of times that the error is to occur to 1, the

above condition does not need to be satisfied.
The following shows the sub-parameters that should be specified: the

error monitoring interval and the number of times that the error is to

occur:

-intvl error-monitoring-interval

Specify the monitoring interval for an intermittent error. Use a value

from 1 to 1440 minutes. The default is 30.
During intermittent error monitoring, if changes are made to the

intermittent error monitoring interval setting or the setting for the

number of times that an error is to occur, the error count and the

elapsed time measured since monitoring has started are reset to 0.
When intermittent error monitoring is not being performed, if changes

are made in the settings of the intermittent error monitoring interval

or the number of times that an error is to occur, the new settings will

take effect after the next time an automatic failback is successful.

Because the errors and elapsed time are not counted or measured

while intermittent errors are not being monitored, the values will not

change.
The monitoring interval specified in this parameter is stored even

though specifying -iem off disables intermittent error monitoring.

Therefore, when you re-enable intermittent error monitoring and a

monitoring interval is not specified, error monitoring will be performed

by using the stored monitoring interval.

-iemnum number-of-times-error-is-to-occur

Specify the number of times the error is to occur. Valid values are

from 1 to 99. The default is 3.
During intermittent error monitoring, if you change the number of

times that the error is to occur in order for the system to determine

that an intermittent error has occurred, the number of errors and the

time that has passed since intermittent error monitoring has started

are reset to 0. The changed setting will take effect immediately and

intermittent error monitoring will restart.
When intermittent error monitoring is not being performed, if you

change the number of times that the error is to occur in order for the

system to determine that an intermittent error has occurred, the new

value will take effect after the next automatic failback successfully