The paths to be placed offline can be specified by using an HBA port, CHA

port, single path, or HBA port WWN. For details on how to specify paths,

see

offline (Places Paths Offline) on page 6-6

.

For example, if you want to place all the paths that pass through a

specific HBA port offline, execute the dlnkmgr command's offline

operation with the -hba parameter specified. The following shows an

example of executing this command:

PROMPT>dlnkmgr offline -hba 1.1

KAPL01055-I All the paths which pass the specified HBA port will

be changed to the Offline(C) status. Is this OK? [y/n]:y

KAPL01056-I If you are sure that there would be no problem when

all the paths which pass the specified HBA are placed in the

Offline(C) status, enter y. Otherwise, enter n. [y/n]:y

KAPL01061-I 3 path(s) were successfully placed Offline(C); 0

path(s) were not. Operation name = offline

PROMPT>

3

.

Check to see if the statuses of all the applicable paths have changed.
The following example shows how to execute the command:

dlnkmgr view -path

Viewing LU Information

This section explains how to display LU information by using an HDLM

command.

To display LU information, execute the dlnkmgr command's view operation

with the -lu parameter specified. The following shows an example in which

the command is executed:

PROMPT>dlnkmgr view -lu

Product : 9500V

SerialNumber : 3679

LUs : 3

iLU HDevName PathID Status

0110 G 000002 Online

000008 Online

0111 F 000001 Online

000007 Online

0112 E 000000 Online

000006 Online

Product : 9970/9980

SerialNumber : 15001

LUs : 3

iLU HDevName PathID Status

0580 J 000005 Online

000011 Online

0585 I 000004 Online

000010 Online

058A H 000003 Online

HDLM Operation