Collecting audit log data, Dlmgetras) -37, Collecting audit log data -37 – HP XP7 Storage User Manual

Page 57

Advertising
background image

¢

Collects error information from the Warning level and higher.

¢

Collects error information from the Information level and higher

(information from all the levels is collected).

¢

Collects error information from the Information level and higher

(including maintenance information).

Collection levels for log information in trace files:

¢

Outputs no trace information

¢

Outputs error information only

¢

Outputs trace information on program operation summaries

¢

Outputs trace information on program operation details

¢

Outputs all trace information

For details on how to change the collection level, see

Setting Up the HDLM

Functions on page 3-72

.

Collecting Error Information Using the Utility for Collecting HDLM

Error Information (DLMgetras)

HDLM provides the DLMgetras utility for collecting HDLM error information.

By using the DLMgetras utility, you can simultaneously collect all the

information required for analyzing errors: information such as error logs,

integrated trace files, trace files, definition files, and information on the OS.

You can use the collected information for when you contact your HDLM

vendor or maintenance company.

For details on the DLMgetras utility, see

The DLMgetras Utility for Collecting

HDLM Error Information on page 7-2

.

Collecting Audit Log Data

HDLM and other Hitachi storage-related products provide an audit log

function so that compliance with regulations, security evaluation standards,

and industry-specific standards can be shown to auditors and evaluators. The

following table describes the categories of audit log data that Hitachi storage-

related products can collect.

Table 2-9 Categories of Audit Log Data That Can Be Collected

Category

Explanation

StartStop

An event indicating the startup or termination of hardware

or software, including:

OS startup and termination

Startup and termination of hardware components

(including micro-program)

HDLM Functions

2-37

Hitachi Dynamic Link Manager (for Windows®) User Guide

Advertising
This manual is related to the following products: