Configuring the Virtual Connect domain using the CLI 143

VCM can be configured so that server blades use server factory default MACs/WWNs or Virtual
Connect-administered MACs/WWNs. These administered values override the default MAC addresses and

WWNs when a server profile is assigned to a server, and appear to pre-boot environments and the host
operating system software as the hardware addresses. To use administered MAC/WWN addresses, select
a range of HP pre-defined or user-specified MAC addresses.
Review the following list of guidelines before creating and deploying server profiles:

IMPORTANT:

Before assigning a profile, unassigning a profile, or modifying a profile, be sure to

review the "Server blade power on and power off guidelines (on page

147

)."

The server blade firmware and option card firmware must be at a revision that supports Virtual Connect
profile assignment. See the HP website (

http://www.hp.com/go/bladesystemupdates

).

Before creating the first server profile:

o

Select whether to use assigned serial numbers or factory default serial numbers.

o

Select whether to use movable, administered MAC addresses and WWNs, or the local server blade
factory default MAC addresses and WWNs.

After an enclosure is imported into a Virtual Connect domain, server blades are isolated from the
networks and SAN fabrics until a server profile is created and assigned.

Server blades must be powered off to receive or relinquish a server profile assignment when using
Virtual Connect-administered MAC addresses or WWNs, or when changing Fibre Channel boot

parameters. When using Flex-10 or FlexFabric modules, there are special considerations for server
power.

When assigning a VC-assigned serial number, the server must be powered off.

FC SAN connections appear in server profile screens only when an HP Virtual Connect Fibre Channel

module is in the enclosure managed by Virtual Connect. FC SAN connections are added in pairs and
cannot be deleted. If an HP Virtual Connect Fibre Channel module is added to a Virtual Connect

domain with existing profiles, an option to add FC connections appears when editing existing profiles.

FCoE connections appear in server profile screens only when an HP VC Flex Fabric 10Gb/24-port

Module is in the enclosure managed by Virtual Connect. FCoE SAN connections are added in pairs. If
an HP VC Flex Fabric 10Gb/24-port Module is added to a Virtual Connect domain with existing
profiles, you can add FCoE connections.

iSCSI connections are not added to server profiles by default. You must add one or more iSCSI
connections. The GUI enables the creation of iSCSI connections only if at least one Flex-10 or FlexFabric

module exists in the domain. The CLI can be used to pre-provision this feature. iSCSI and FCoE
connections cannot share the same physical Flex-10 port since they use the same physical function.

Some server profile SAN boot settings (controller boot order) are applied by Virtual Connect only after

the server blade has been booted at least once with the final mezzanine card configuration.

If PXE, controller boot order, or SAN boot settings are made outside of Virtual Connect using RBSU or

other configuration tools, Virtual Connect restores the settings defined by the server profile after the
server blade completes the next boot cycle.

After Virtual Connect assigns a server profile to a server, RBSU cannot modify the protocol configuration
(iSCSI/FCoE) for any NIC, including the NC551m, even if the NIC is not connected to a Virtual

Connect module. Any protocol configuration changes must be made before the server profile is
assigned to the server.