HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 40

Advertising
background image

Command line 40

Item

Description

->add fcoe-connection MyNewProfile Fabric=SAN_5

Adds a new FCoE connection to a profile

->add fcoe-connection MyNewProfile Fabric=SomeFabric

SpeedType=4Gb

Adds a new FCoE connection and configures the port speed

->add fcoe-connection MyNewProfile

Adds a new FCoE connection and leaves it unassigned

->add fc-connection MyNewProfile Fabric=MyFabric

SpeedType=Custom CustomSpeed=5000

Adds a new FCoE connection and sets a custom speed of 5Gb

->add fcoe-connection MyNewProfile

WWNAddressType=Factory-Default

Adds a new FCoE connection and uses factory-default WWN addresses

->add fcoe-connection MyNewProfile

WWNAddressType=User-Defined

PortWWN=50:06:0B:00:00:C2:62:00

NodeWWN=50:06:0B:00:00:C2:62:01

Adds a new FCoE connection and provides user-defined WWN addresses

->add fcoe-connection MyNewProfile

MACAddressType=Factory-Default

Adds a new FCoE connection and uses factory-default MAC addresses

->add fcoe-connection MyNewProfile

MACAddressType=User-Defined

EthernetMAC=00-17-A4-77-00-00

Adds a new FCoE connection and provides a user-defined MAC address

Item

Description

remove fcoe-connection Remove the last FCoE connection from an existing server profile.

Syntax

remove fcoe-connection <ProfileName>

Parameter

ProfileName (required) The name of an existing profile from which the last FCoE connection is being

removed

Example

->remove fcoe-connection MyProfile

Removes an FCoE connection from a profile

Item

Description

set fcoe-connection

Modify an existing FCoE connection.

Syntax

set fcoe-connection <ConnectionID> [Fabric=<FabricName>]

[SpeedType=<1Gb|2Gb|4Gb|8Gb|Custom|Disabled>]

[CustomSpeed=<100Mb-10Gb>] [BootPriority=<priority>]

[BootPort=<portName>] [BootLun=<LUN>]

Parameters

ConnectionID

(required)

The ID of an existing FCoE connection. The ID format is <ProfileName:Port>.

Properties

Fabric (optional)

The name of the fabric to associate with the connection. The fabric being
specified should be associated with the same bay as the FCoE connection.

SpeedType (optional)

The requested operational speed for the server. Valid values include
"1Gb","2Gb", "4Gb", "8Gb", "Custom", and "Disabled". If the SpeedType is
"Custom", you can configure a speed from 100Mb to 10Gb in 100Mb

Advertising