HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 148

Advertising
background image

Configuring the Virtual Connect domain using the CLI 148

Changing the Fabric connected to a Fibre Channel port

Changing the speed of a Fibre Channel port

Assigning or unassigning server profiles, if server factory defaults are used for MAC addresses and
WWNs, BIOS Fibre Channel boot settings are used, and PXE is not being enabled or disabled (USE

BIOS for all network connections)
Exceptions for Flex-10 connection changes are specified in the following sections.

Flex-10 connection changes that require power off
Always power off server blades with Flex-10 connections in the following instances:

Adding a connection that is mapped to Flex-10

Removing a connection that is mapped to Flex-10

Assigning a profile to a server that maps Flex-10 connections

Unassigning a profile with Flex-10 connections

Flex-10 connection changes that do not require power off
With Virtual Connect Manager v2.10 and higher, it is not necessary to power off a server blade with Flex-10
connections in the following instances:

Changing a connection's network:

o

From a single network to another single network

o

From a single network to multiple networks

o

From multiple networks to a single network

Modifying the networks or VLAN IDs in a connection with multiple networks

With Virtual Connect Manager v2.30 and higher, it is not necessary to power off a server blade with Flex-10
connections in the following instances:

Changing a connection's network:

o

From "unassigned" to a single network

o

From a single network to "unassigned"

o

From "unassigned" to multiple networks

o

From multiple networks to "unassigned"

Changing the requested bandwidth

FCoE connection changes that require power off

Adding an FCoE connection to an assigned server profile

Removing an FCoE connection from an assigned server profile

Assigning a profile containing FCoE connections to a server

Changing FCoE boot parameters

Restart after OA credential recovery
The state, "profile recovered," is applied to servers that are powered on when VC Manager restarts after an

OA credential recovery. When VC Manager detects a restart after a credential recovery, it rewrites the
profile parameters for any server that is powered on, connects the server to the appropriate Ethernet networks

and FC fabrics, and then puts the server and profile in the "profile recovered" state. The server and profile

Advertising