Interconnect – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 43

Command line 43
Item
Description
show igmp-group
Display interconnect module IGMP Group table information for the specified module.
Syntax
show igmp-group <ModuleID>
Parameter
ModuleID
(required)
The ID of the module for which to display the IGMP Group table. The ID is in the format
of <EnclosureID>:<BayNumber>.
Example
->show igmp-group enc0:1
Displays the IGMP Group information for the module in bay 1 of enclosure enc0
interconnect
Manage I/O interconnect modules.
Supported actions: add, help, remove, set, show
Item
Description
add interconnect
Add an interconnect module to an imported enclosure.
Syntax
add interconnect <module ID> type=<moduleName>
Parameter
module ID(required)
The bay identifier within an existing network in the domain. For example, bay 3
in the local enclosure has a module ID of enc0:3.
module (required)
The name of the interconnect module. Use:
•
type=vcenet for an HP 1/10Gb VC-Enet Module
•
type=vcenet2 for an HP 1/10Gb-F VC-Enet Module
•
type=vcenet3 for an HP VC Flex-10 Enet Module
•
type=vcenet5 for an HP FlexFabric 10Gb/24-port Module
•
type=vcfc for an HP 4Gb VC-FC Module
•
type=vcfc2 for an HP VC 8Gb 24-Port FC Module
•
type=vcfc3 for an HP VC 8Gb 20-Port FC Module
Example
->add interconnect enc0:3 module=vcenet5
Adds an HP VC FlexFabric 10Gb/24-port Module to bay 3 of enclosure enc0
Item
Description
remove interconnect
Remove an interconnect module from the domain. Normally, this command is
used if a module has been physically removed from the enclosure. To be
removed, the module must not be currently in use by any element in the domain.
Syntax
remove interconnect <ModuleID|*>
Parameter
ModuleID(required)
The ID of the module to remove. The ID format is
<EnclosureID>:<BayNumber>. Use <EnclosureID:*> to remove all
interconnect modules that are physically present in the enclosure from the
domain. Use <*:BayNumber> to remove all interconnect modules in the
specified bay that are not physically present in any enclosures from the domain.
Use "*" to remove all interconnect modules that are not physically present in any
enclosure from the domain.
To display a list of the IDs corresponding to modules in the domain, use the show
interconnect command.
- 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem