Introduction 12

BladeSystem c7000 enclosures and G6 or newer server blades with Virtual Connect firmware v3.15 and
later.
VC-Enet modules enable connectivity to all brands of data center Ethernet switches. VC-Enet modules can
also be directly connected to other types of devices, such as printers, laptops, rack servers, and network
storage devices.
The VC-FC and FlexFabric modules enable connectivity of the enclosure to Brocade, Cisco, McDATA, or
QLogic data center FC switches. Every FC fabric is limited in the number of switches it can support, but the

VC-FC modules do not appear as switches to the FC fabric and do not count against FC fabric limits.
A basic Virtual Connect domain includes a single HP c-Class BladeSystem c7000 Enclosure for a total of 16
servers (or up to 32 servers if the double-dense option is enabled), or a single HP c-Class BladeSystem c3000

Enclosure for a total of 8 servers (or up to 16 servers if the double-dense option is enabled). For more
information on the double-dense option, see "Double-dense server bay option" in the user guide. Within the
domain, any server blade with the requisite LAN or SAN devices can access any LAN or SAN connected to

a VC module, and a server blade of a given processor type (Integrity or X86) can be used as a spare for any
server blade of the same processor type within the same enclosure, as long as the server has the requisite

number and type of connections. Using network access groups feature, the network administrator can clearly
define a separation of networks based on their allowed functionality and prevent the server administrator
from assigning specific network combinations in the same server profile.
By stacking (cabling) the VC-Enet modules together within the domain and connecting the VC-FC or
FlexFabric module FC uplinks on the same bay of all enclosures to the same FC switch, every server blade in

the domain can be configured to access any external network or fabric connection. With this configuration,
you can use VCM to deploy and migrate a server blade profile to any server in the Virtual Connect domain
without changing external LAN or SAN configurations.

Using multiple enclosures

Multiple enclosure support enables up to four c7000 enclosures to be managed within a single Virtual

Connect domain for a total of 128 servers, if double-dense support is enabled while using the Domain Setup
Wizard. There are 16 half-height or 8 full-height server bays in a c7000 enclosure. A combination of

full-height and half-height servers can be used in the same enclosure.
Multiple enclosure domains are not supported on c3000 enclosures. The VC-Enet or FlexFabric modules use
stacking cables between enclosures so that network traffic can be routed from any server Ethernet port to any

uplink within the VC domain. Since FC does not support stacking, the VC-FC or FlexFabric module FC uplinks
on the same bay of all enclosures must be connected to the same FC switch to enable profile mobility.
The management interfaces for all enclosure Onboard Administrators and VC modules within the same VC

domain must be on the same lightly loaded subnet and highly reliable network. Overloads or loss of
connectivity can disable configuration attempts until the connectivity is re-estabilished and synchronized with

the domain. The Onboard Administrator IP addresses used must be configured to be static. The Onboard
Administrator user credential for all enclosures must be consistent to enable VCSU firmware updates for VC
modules in the remote enclosures. All FC-capable modules in the same horizontally adjacent bay pair (bays

1-2, 3-4, and so on) must be of the same type and position in all enclosures.
Multi-enclosure double-dense domains require similar and compatible VC-FC modules in bays 5, 6, 7, and
8 in all enclosures if FC connectivity is required. If a multi-enclosure double-dense configuration contains

incompatible VC-FC modules in bays 5, 6, 7, or 8 in the local or remote enclosures, some or all of the
compatible VC-FC modules in the remote enclosures might be designated INCOMPATIBLE after import.