Adding uplink ports to an ethernet network, Modifying uplink port properties, Creating a shared uplink set – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 138: Displaying shared uplink sets, Adding uplink ports to a shared uplink set

Advertising
background image

Configuring the Virtual Connect domain using the CLI 138

>add network Network1 nags=DatabaseNetGroup,AccessNetGroup

Adding uplink ports to an Ethernet network

To add uplink ports to an existing Ethernet network, use the add uplinkport command:

>add uplinkport enc0:1:1 network=MyNetwork

Modifying uplink port properties

To modify an uplink port that exists as a member of a network or shared uplink set, use the set uplinkport

command:

>set uplinkport network=Network1 speed=1Gb

Creating a shared uplink set

To create a shared uplink set, use the add uplinkset command:

>add uplinkset MyUplinkSetName

A shared uplink set identifies VC-Enet module uplinks that carry multiple networks over the same cable or set
of cables. In this case, each Ethernet packet carries a VLAN tag (IEEE 802.1Q) to identify the specific

network to which it belongs. On shared uplinks, the VLAN tags are added when packets leave the
VC-enabled enclosure and are removed when packets enter the enclosure. The external Ethernet switch and
VCM must be configured to use the same VLAN tag identifier (a number between 1 and 4094) for each

network.
Virtual Connect places no special restrictions on which VLAN identifiers can be used, so the VLAN IDs

already used for the networks in the data center can be used on these shared uplinks. To configure a shared
uplink set for VLAN tagging, obtain a list of the network names and their VLAN IDs.
A shared uplink set enables multiple ports to be included to support port aggregation and link failover with

a consistent set of VLAN tags.
Because VLAN tags are added or removed when Ethernet packets leave or enter the VC-Enet shared uplink,
the VLAN tags have no relevance after the Ethernet packet enters the enclosure.
Identifying an associated network as the native VLAN causes all untagged incoming Ethernet packets to be
placed onto this network. Only one associated network can be designated as the native VLAN. All outgoing

Ethernet packets are VLAN-tagged.

Displaying shared uplink sets

To display shared uplink sets, use the show uplinkset command:

Summary for all shared uplink sets
>show uplinkset

Details for all shared uplink sets
>show uplinkset *

Details for a single shared uplink set
>show uplinkset MyUplinkSetName

Adding uplink ports to a shared uplink set

To add uplink ports to a shared uplink set, use the add uplinkport command: