Full sweep test, Dlt sram check test (short and long versions) – HP Library and Tape Tools User Manual

Page 107

Advertising
background image

Table 27 SDLT Tape Edge Damage (TED) test details (continued)

SDLT Tape Edge Damage (TED) test

Details/System Performance
test

Other notes

This test assumes:

The SDLT tapes have the proper bar code labels with S as the 7th character.

The SDLT drives have the latest firmware.

The library is configured to show all bar code labels. Otherwise, the tapes may
not be recognized with this test.

If this test is run on a library with no SDLT 220 or SDLT 320 drives, it will not fail,
nor will it check anything. It will return “There were no errors identified”.

Although primarily intended for libraries, this test is also supported on SDLT 220
and 320 standalone drives. For standalone drive testing, run Device Analysis on
the drive to get the media ID of the currently loaded tape.

NOTE:

For instructions on how to perform this test, see

“Running tests and

device-specific utilities” (page 29)

or

“Running the tests (CSI)” (page 50)

.

ESL 9000 and MSL libraries with SDLT 230, SDLT 320, or SDLT 600 drives; and SDLT
230, SDLT 320, or SDLT 600 standalone drives.

Available for

Full Sweep test

Table 28 Full Sweep test details

Full Sweep test

Details/System Performance
test

This test script moves the robotics through the full range of motion to help prevent
reliability issues with the brush tracks. This test is available for the C7200 and C7145
library models.

Description

NOTE:

For instructions on how to perform this test, see

“Running tests and

device-specific utilities” (page 29)

or

“Running the tests (CSI)” (page 50)

.

Run this test if the results of a Device Analysis test recommend that you run this test.
This recommendation is based on reviewing library log data for certain critical errors,
including those related to issues with the brush tracks.

When to run

Up to 2.5 hours, depending on whether the long or short test is selected.

Average duration

Test will not overwrite any data on the media. Data from this test is logged into the
library for future use by support personnel.

Other notes

C7145 and C7200 libraries

Available for

DLT SRAM Check test (short and long versions)

CAUTION:

These tests are destructive and will overwrite data on the media that is present in your

product.

Table 29 DLT SRAM Check test details

DLT SRAM Check test

Details/System Performance
test

These tests check DLT 8000 drive logs for evidence of SRAM chip corruption, and they
perform a read/write test to check the drive for susceptibility to SRAM corruption

Description

problems. The tests are destructive to data on the cartridge in the drive. These tests
are only available for DLT drives.

Performance tests 107