HP EX475 MediaSmart Server User Manual

Page 120

Advertising
background image

Troubleshooting

Version Update 1.1.1

7-6

The HP MediaSmart Server monitors the temperature of the system,

microprocessor (CPU), fan speed, and voltages. It displays the following

messages:

Temperature warnings

Fan speed warnings

Voltages warnings

Temperature warnings

Temperature warning messages indicate that some server components are too

hot.

To lower the temperature of the server

1

Check the ventilation surrounding the server:

ƒ

If the server is located in a small unventilated space, move the server

to a more ventilated location.

ƒ

Check that the server’s front and back panels are not blocked.

ƒ

Check that the location of the server is not too hot. Maximum

environmental temperature for operating the server is 35° C (95° F).

2

Remove any accumulated dust on the back and front of the server.

3

Fold up the flap on any empty system drive trays. For more information,

see

Installing an internal SATA drive on page 6-5

.

4

If none of the previous steps return the temperature to normal:

a

Write down the temperatures of the CPU and System.

b

Turn off the server.

c

Contact HP Support at

http://www.hp.com/support

.

Fan speed warnings

The fans cool the disk drives and other electronics. If they are not cooling the

server sufficiently, the hard drives and server may be damaged.

For fan speed out of specification

1

Write down the speeds of the upper and lower fans.

2

Turn off the server.

3

Contact HP Support at

http://www.hp.com/support

.