Note for Dual A/F channel units: You can program each analog output to represent the
data from sensor 1 or 2 by selecting the appropriate radio box.

Factory Programmed Defaults:

Single Channel A/F units: Analog Output 1 is programmed to output between 0 V for an
AFR of 7.35 (gasoline) and 5.0V for an AFR of 22.39. Analog Output 2 simulates a
typical narrow band oxygen sensor. The configuration is 1.1 V for an AFR of 14 and .1 V
for an AFR of 15.

Dual Channel A/F units
: Analog Output 1 and Analog Output 2 are programmed to
output between 0 V for an AFR of 7.35 and 5.0V for an AFR of 22.39. They represent
sensor 1 and sensor 2, respectively.

Other curves, of course, are easily programmable.

5.3.2

Advanced output programming


The ‘Advanced’ button allows programming to set the analog out update speed and the
voltage output during sensor Warm-up and Error Condition. The factory defaults of the
analog outputs is to update the outputs 1/12 of a second. The factory default voltage
output is set for 0 volts for both the Warm-up and Error Condition.


When setting the LM-2 to the slower response speed settings the measured mixture
data will be averaged over the response time setting before being output.