F. PROGRAM LOCATION 03 (PL03)

HI Temp

Location to be viewed/changed.

Press “Perm Press” key.

Display will read “HI°F,” “HI Temp” key
status for 3-seconds and then the actual
temperature programmed. If no changes,
press “Perm Press” key otherwise press
“HI” or “LO” keys and then “Perm Press”
key.

Temperature Increase

Temperature Decrease

Summary: HI Temp is programmable from a minimum of 100° F to a maximum of 190° F in ten-degree increments

or from a minimum of 38° C to a maximum of 88° C in five-degree increments.

For the AD-26 and AD-295 any three (3) of the selections (HI/LO/PP) are programmable from a
minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C to
a maximum of 77° C in five-degree increments.

For the AD-540 and WDA-540 any three (3) of the selections (HI/LO/PP) are programmable from
a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C
to a maximum of 71° C in five-degree increments.

PL03

HI°F

Automatically goes into PL04

Program without PL04 Display

Mode

Perm Press

180F

HI Temp

Perm Press

LO Temp

Refer to Section V for instructions

on entering program locations.

(Wait 3-Seconds)