Program location 06 (pl06), I. program location 06 (pl06) – ADC Gas Electric Steam WDA-540 User Manual

Page 42

Advertising
background image

40

I. PROGRAM LOCATION 06 (PL06)

LO Temp cool down temperature/time

PL06

LOCd

Perm Press

·

100

·

2

HI Temp

Perm Press

LO Temp

Refer to Section V for instructions

on entering program locations.

(Wait 3-Seconds)

100

·

2

LO Temp

HI Temp

Perm Press

PL07

Proceed to next location

to be changed

To exit program mode,

open program switch

Location to be viewed/changed.

Press “Perm Press” key.

Display will read “LOCd,” LO Temp
cool down status for 3-seconds and then
the actual temperature and time
programmed. If no changes, press “Perm
Press” key twice, otherwise press “HI” or
“LO” keys and then “Perm Press” key.

Temperature Decrease

Temperature Increase

Time Decrease

Time Increase

Summary:

Cool down temperature is programmable from a minimum of 70° F to a maximum of 190° F in ten
degree increments or from a minimum 21° C to a maximum of 88° C in five-degree increments.

For the AD-26 and AD-295 any three (3) of the selections (HI/LO/PP) are programmable from a
minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C
to a maximum of 77° C in five-degree increments.

For the AD-540 and WDA-540 any three (3) of the selections (HI/LO/PP) are programmable
from a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of
38° C to a maximum of 71° C in five-degree increments.

Cool down is programmable from 0 to 9 minutes.