G. program location 04 (pl04) – ADC Gas Electric Steam WDA-540 User Manual

Page 40

Advertising
background image

38

G. PROGRAM LOCATION 04 (PL04)

HI Temp cool down temperature/time

Location to be viewed/changed.

Press “Perm Press” key.

Display will read “HICd,” HI Temp
cool down status for 3-seconds and then
the actual temp and time programmed.
If no change press “Perm Press” key twice,
otherwise press “HI” or “LO” keys and
then “Perm Press” key.

Summary: Cool down temperature is programmable from a minimum of 70° F to a maximum of 190° F in ten

degree increments or from a minimum of 21° C to a maximum of 88° C in five-degree increments.

For the AD-26 and AD-295 any three (3) of the selections (HI/LO/PP) are programmable from a
minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C to
a maximum of 77° C in five-degree increments.

For the AD-540 and WDA-540 any three (3) of the selections (HI/LO/PP) are programmable from

a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C
to a maximum of 71° C in five-degree increments.

Cool down is programmable from 0 to 9 minutes.

PL04

HICd

Perm Press

·

100

·

2

HI Temp

Perm Press

LO Temp

Refer to Section V for instructions

on entering program locations.

(Wait 3-Seconds)

Continued from F.

100

·

2

LO Temp

HI Temp

Perm Press

PL05

Proceed to next location

to be changed

To exit program mode,

open program switch

Temperature Decrease

Temperature Increase

Time Decrease

Time Increase