Q. program location 14 (pl14) – ADC Gas Electric Steam WDA-540 User Manual

Page 50

Advertising
background image

48

Q. PROGRAM LOCATION 14 (PL14)

Maximum Time for Auto Dry

Location to be viewed/changed.

Press “Perm Press” key.

Display will read “Adrt,” automatic
maximum drying time for 3-seconds
and then time programmed. If no
change, press “Perm Press” key,
otherwise press “HI” or “LO”
keys and then “Perm Press” key.

Summary: The maximum auto dryness time is programmable from 1 to 99 minutes.

PL14

Adrt

Perm Press

25

HI Temp

Perm Press

LO Temp

Refer to Section V for instructions

on entering program locations.

(Wait 3-Seconds)

("Hold In" to Accelerate)

("Hold In" to Accelerate)

PL15

Proceed to next location

to be changed

To exit program mode,

open program switch

Time Decrease

Time Increase