ADC Gas Electric Steam WDA-540 User Manual

Page 52

Advertising
background image

50

S. PROGRAM LOCATION 16 (PL16) AND PROGRAM LOCATION 17 (PL17)

Maximum Active Anti-Wrinkle Time

Location to be viewed/changed.

Press “Perm Press” key. Display
will read “AGt,” maximum guard
time for 3-seconds and then time
programmed. If no change, press
“Perm Press” key, otherwise press
“HI” or “LO” keys and then “Perm
Press” key.

Location to be viewed/changed.

Press “Perm Press” key. Display
will read “A,” and factor programmed
for 3-seconds. If no change, press
“Perm Press” key, otherwise press
“HI” or “LO” keys and then “Perm
Press” key.

Display will read “B,” and factor
programmed for 3-seconds. If no
change, press “Perm Press” key,
otherwise press “HI” or “LO” keys
and then “Perm Press” key.

PL16

AGt

Perm Press

10

HI Temp

Perm Press

LO Temp

Refer to Section V for instructions

on entering program locations.

(Wait 3-Seconds)

A 6

("Hold In" to Accelerate)

("Hold In" to Accelerate)

LO Temp

Perm Press

B 65

Proceed to next location

to be changed

To exit program mode,

open program switch

("Hold In" to Accelerate)

("Hold In" to Accelerate)

PL17

Refer to Section V for instructions

on entering program locations.

Perm Press

A 6

(Wait 3-Seconds)

B 65

Perm Press

70F

LO Temp

HI Temp

HI Temp

("Hold In" to Accelerate)

("Hold In" to Accelerate)

Time Decrease

Time Increase

Factor Increase

Factor Increase

Factor Decrease

Programmable 1 to 9

Programmable 1 to 99