Chapter 16 _____________________________________________________ Serial Line Commands

VAISALA _______________________________________________________________________ 87

command R does not change the default operation mode set with the
command SMODE.

Example:

>r
0.000 'C 0.00 'C 0.00 hPa 0.00
slpm
0.000 'C 0.00 'C 0.00 hPa 0.00
slpm

S Stopping the Continuous Output

Syntax:

S<cr>

Type S to stop outputting.

ADDR Setting the Device Address

Syntax:

ADDR xx<cr>

where
xx =

0...99 (address)

The address is used in POLL mode when more than one device is
connected to one serial line.

SEND Outputting One Single Reading

Syntax:

SEND x<cr>

where
x

=

device address (0...99) in POLL state

INTV Setting the Output Interval

Syntax:

INTV xxx yyy<cr>

where
xxx

=

output interval

yyy

=

unit (s, min, h)