8

Chapter 3: Mounting and Wiring

9

Installation and Programming Manual

Chapter 3: Mounting and Wiring

Chapter 3: Mounting and Wiring

This chapter provides instructions for mounting and wiring the shut height monitor. These
instructions have been divided into two sections: Section 3.1: Mounting and Section 3.2:
Wiring.

Things to Consider

It is recommended that you consider the following before installing the shut height monitor:

To minimize the effects of electromagnetic interference (EMI), the monitor
should be mounted as far away as possible from motor starters and control
relays.

The monitor should be mounted in an area free of water spray, corrosive gases,
flying chips, or any other foreign matter that could cause damage to the unit.

If the monitor is mounted directly on the press, it should be installed in an area
where shock and vibration will be minimized.

The monitor should be located in an area that is within the temperature and
humidity specifications. (See Appendix D: Specifications.)

Controller

To assist you in mounting the shut height monitor, refer to Figure 3-1. Perform the following
steps:

1. According to the dimensions as shown in Figure 3-1, cut out a section of the

panel you wish to mount the monitor to.

2. Remove the mounting rails on the left and right side of the unit by removing

the #6-32 UNC screws located on the rear of the unit.

3. Place the monitor in the newly cutout section of the panel.

4. From behind the panel, insert the two mounting rails into the monitor’s side

grooves. The feet of the rails must be inserted first. See Figure 3-1 for the
location of the mounting rails.

The mounting rails secure the monitor by their feet being pressed against the

back of the panel.