The following chart contains errors that will cause the fault check relay to open:

Chart A-4 Fault Check Relay Errors

Error Displayed

Error Description

Solution

EEr 1

An invalid function number was
entered.

Enter a valid function number.

EEr 2

An invalid system configuration was
entered.

Enter a valid system configuration.

EEr 3

A value outside the function's ac-
ceptable range was entered.

Review function's range and re-en-
ter value.

EEr 4

An incorrect parameter was entered. Contact GEMCO Tech. Support.

EEr 5

A value was programmed into the
Lower End Limit function that is
greater than the value programmed
in the Upper End Limit function.

Program a value that is less than
the value programmed in the Upper
End Limit function.

EEr 6

The value programmed into the Up-
per End Limit function is less than
the value programmed in the Lower
End Limit function.

Program a value that is greater than
the value programmed in the Lower
End Limit function.

Chart A-3: Entry Errors

Error Displayed

Error Description

SEr101

A configuration error occurred.

SEr106

Firmware CRC error occurred.

SEr320

This is resolver-specific error. See Chart A-6.

SEr330

The input device is not connected to the monitor's input module.

SEr331

This is an LDT-Specific Error. See Chart A-7.

OEr101

The press's ram did not move within the time programmed in the Move
Detection Time-out function.

OEr330 or
OEr320

The press's shut height moved beyond the value programmed in the Nega-
tive Over Travel Limit function.