Installation and Programming Manual

30

Chapter 4: Programming

31

Installation and Programming Manual

Chapter 4: Programming

Count Direction (301)

The Count Direction function is used to change the direction the shut height position will move
as the LDT’s magnet travels along the guide rail. A 0 value will cause the position to increment
as the magnet moves away from the LDT head. A value of 1 will cause the position to increment
as the magnet moves toward the LDT head. The default for this function is 1. For further
explanations, see Figure 4-2. To change the value of the Count Direction function, perform the
following steps:

1. Select the function key.

The monitor displays “F-----”.

2. Select function number 301 . Select the enter key.

The monitor displays the function’s current value.

3. Enter either a 0 or 1. Select the enter key.

301

Enter either
0 or 1

Figure 4-2 Count Direction Function

Count Direction Function = 0

Count Direction Function = 1

100

100

When the Count Direction Function is
programmed with a value of 0, the
monitor will increment when the LDT’s
magnet assembly is moving away from
the head of the LDT.

When the Count Direction Function is
programmed with a value of 1, the
monitor will increment when the LDT’s
magnet assembly is moving toward the
head of the LDT.

0

0

(F)

8

8