Wire Speed (300)

Programming of the wire speed synchronizes the performance of the module with the performance
of the LDT. You will find the wire speed on the legend plate of your LDT.

To program wire speed, perform the following steps:

1. Select the function key.

The monitor displays “F-----”.

2. Select function number 300 . Select the enter key.

The monitor displays the function’s current value.

3. Enter the new wire speed value. Select the enter key. Count Direction (301)

300

Enter new
value

4.2

Option V1 - This module can only be used with Gemco LDTs with a part number starting with
951VP1992 or 951VP2110.

Wire speed and recirculations for these LDTs have been configured at the factory for maximum
resolution.

NOTE: Always refer to the LDT legend plate for programming wire speed (Function 300). The

wire speed will always be between 500.000 and 600.000 micro sec./inch.

Option L1 - This module is designed to be used with any LDT with digital output. These
include Series 951, 952 with VP, RS or CP outputs.

This module provides faster updates of position while using the LDT with standard wire speeds.

NOTE: Review the LDT legend plate for correct wire speed. Wire speed will always be

between 8.000 and 10.000 micro sec./inch.

NOTE: If option L1 is used, the first step in configuration must be Function 307 (LDT Type)

that tells the module which LDT is being used.

NOTE: Before an LDT configuration function can be programmed, the shut height monitor

must be in program mode. To put the monitor in program mode, see Program Mode
Access in Section 4.6: Program and Supervisory Mode Functions.